Njengerhasi yokubulala iintsholongwane, i-ozone isetyenziswa ngakumbi nangakumbi kwiinkalo ezahlukeneyo, ngoko ke kubaluleke kakhulu ukuqonda imigangatho ehambelanayo yoxinaniso kunye neenkcukacha.
Utshintsho kwiMigangatho yeMpilo yoMsebenzi yaseTshayina
Kumgangatho omtsha, ubuninzi obuvumelekileyo boxinaniso lwemichiza eyingozi, kubandakanywa i-ozone, luchaziwe, oko kukuthi, ukuxinwa kweekhemikhali ezinobungozi nangaliphi na ixesha kunye nendawo yokusebenza akufanele kudlule i-0.3mg/m³ ngosuku lokusebenza.
Iimfuno zoxinaniso lokukhutshwa kwe-ozone kwiinkalo ezahlukeneyo
Ngokusetyenziswa ngokubanzi kwe-ozone kubomi bemihla ngemihla, imigangatho efanelekileyo kunye neemfuno ziye zaqulunqwa kwiinkalo ezahlukeneyo.Nantsi eminye imizekelo:
Izicoci zomoya zekhaya kunye nezixhobo zombane ezifanayo: Ngokwe “IiMfuno eziKhethekileyo zeZicoci zoMoya ezine-Antibacterial, Sterilizing kunye neMisebenzi yokuSungula kuMzi kunye neZixhobo zoMbane ezifanayo” (GB 21551.3-2010), ugxininiso lwe-ozone kufuneka lube ngu-≤0.10mg kwi-5cm ukusuka kwi-5cm indawo yokukhupha umoya./m³.
IKhabhinethi ye-Medical Ozone Disinfection: NgokweKhabhinethi ye-Medical Ozone Disinfection (YY 0215-2008), isixa esishiyekileyo segesi ye-ozone akufanele sibe sikhulu kune-0.16mg/m³.
Ikhabhinethi ye-Tableware disinfection: Ngokutsho "kweeMfuno zoKhuseleko kunye noCoceko kwiiKhabhinethi zeTableware Disinfection" (GB 17988-2008), kumgama we-20cm ukusuka kwikhabhinethi, i-concentration ye-ozone akufanele idlule i-0.2mg / m³ yonke imizuzu emibini ngemizuzu eyi-10.
I-Ultraviolet air sterilizer: Ngokutsho koMgangatho woKhuseleko kunye noCoceko lwe-Ultraviolet Air Sterilizer (GB 28235-2011), xa kukho umntu, ubuninzi obuvumelekileyo bokugxininiswa kwe-ozone kwindawo yomoya yangaphakathi kwiyure enye xa inzalo isebenza yi-0.1mg. /m³.
IiNgcaciso zobuGcisa zokuDilwa kweeNtsholongwane kuMaziko oNyango: Ngokwe “Ngcaciso yobuGcisa yokuDilwa kweeNtsholongwane kuMaziko oNyango” (WS/T 367-2012), xa abantu bekhona, ukugxininiswa kwe-ozone okuvumelekileyo emoyeni wangaphakathi yi-0.16mg/m³.
Ngokusekelwe kule migangatho ingentla, kunokubonwa ukuba ubuninzi obuvumelekileyo be-ozone yi-0.16mg/m³ xa kukho abantu, kwaye iimfuno ezingqongqo zifuna ukuba ugxininiso lwe-ozone aludluli i-0.1mg/m³.Kufuneka kuqatshelwe ukuba iimeko ezahlukeneyo zokusetyenziswa kunye neemeko zinokwahluka, ngoko ke imigangatho ehambelanayo kunye neenkcukacha kufuneka zilandelwe kwizicelo ezithile.
Kwintsimi ye-ozone disinfection, enye imveliso eye yatsala ingqalelo enkulu yi-anesthesia yokuphefumla i-circuit sterilizer.Le mveliso ayisebenzisi kuphela izinto ze-ozone zokubulala iintsholongwane, kodwa ikwadibanisa izinto ezintsonkothileyo zokubulala iintsholongwane zotywala ukuphumeza iziphumo ezingcono zokubulala iintsholongwane.Nazi iimpawu kunye neenzuzo zale mveliso:
Uxinzelelo olusezantsi lwe-ozone emission concentration: I-ozone emission concentration ye-anesthesia breathing circuit umatshini wokubulala iintsholongwane kuphela yi-0.003mg/m³, engaphantsi kakhulu kunowona mxinwa uphezulu ovumelekileyo we-0.16mg/m³.Oku kuthetha ukuba ngexesha lokusetyenziswa, imveliso iqinisekisa ukhuseleko lwabasebenzi ngelixa ibonelela nge-disinfection esebenzayo.
I-Compound disinfection factor: Ukongeza kwi-ozone disinfection factor, i-anesthesia breathing circuit sterilizer ikwasebenzisa i-alcohol disinfection factor.Oku kudityaniswa kweendlela ezimbini zokubulala iintsholongwane kunokubulala ngokucace ngakumbi iintsholongwane ezahlukeneyo ze-pathogenic ngaphakathi kumatshini wokuthomalalisa iintsholongwane okanye i-ventilator, ngokufanelekileyo ukunciphisa umngcipheko wosulelo olunqamlezayo.
Ukusebenza okuphezulu: I-anesthesia yokuphefumla i-circuit sterilizer ine-high-effective disinfection performance kwaye inokugqiba inkqubo yokukhupha iintsholongwane ngexesha elifutshane.Oku kunokuphucula ukusebenza kakuhle, ukonga ixesha, kunye nokuqinisekisa ukubulawa kweentsholongwane kwiisekethe zangaphakathi zomatshini we-anesthesia kunye ne-ventilator.
Kulula ukusebenza: Le mveliso ilula kuyilo kwaye kulula ukuyisebenzisa.Abasebenzisi kufuneka balandele imiyalelo kuphela ukugqiba inkqubo yokubulala iintsholongwane.Kwangaxeshanye, umatshini wokuphefumla i-anesthesia wesiphaluka wokubulala iintsholongwane nawo uxhotyiswe ngamanyathelo okuthintela ahambelanayo okuthintela ukungcoliseka okwesibini emva kokusetyenziswa.
Shwankathela
Imigangatho yogxininiso lokukhutshwa kwegesi ebulala iintsholongwane i-ozone iyahluka kwiinkalo ezahlukeneyo, kwaye iimfuno zabantu zingqongqo.Ukuqonda le migangatho kunye neemfuno kunokusenza siqonde ngakumbi iimfuno zomgangatho kunye nemimiselo yendawo esihlala kuyo. Xa sisebenzisa izixhobo ezifanelekileyo zokubulala iintsholongwane, sinokuqinisekisa umphumo wokubulala iintsholongwane kunye nokukhusela impilo yabantu.